5M9M
Human angiogenin PD variant Q77P
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I02 |
Synchrotron site | Diamond |
Beamline | I02 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2016-05-02 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.9795 |
Spacegroup name | P 1 |
Unit cell lengths | 50.170, 50.337, 62.190 |
Unit cell angles | 103.42, 103.59, 110.40 |
Refinement procedure
Resolution | 56.750 - 1.650 |
R-factor | 0.23296 |
Rwork | 0.232 |
R-free | 0.27046 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1ang |
RMSD bond length | 0.012 |
RMSD bond angle | 1.498 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 56.800 | 1.680 |
High resolution limit [Å] | 1.650 | 1.650 |
Number of reflections | 60548 | |
<I/σ(I)> | 7.3 | 1.9 |
Completeness [%] | 96.6 | 70.4 |
Redundancy | 14.8 | 10.8 |
CC(1/2) | 0.988 | 0.622 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 5.5 | 289 | 0.2 M ammonium sulphate 0.1 M bis-tris methane 25% PEG 3350 |