5M81
Translation initiation factor 4E in complex with (SP)-iPr-m7GppSpG mRNA 5' cap analog
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-04-25 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.918 |
Spacegroup name | P 1 |
Unit cell lengths | 38.100, 38.120, 147.240 |
Unit cell angles | 88.77, 95.82, 103.44 |
Refinement procedure
Resolution | 48.827 - 1.900 |
R-factor | 0.1785 |
Rwork | 0.177 |
R-free | 0.21870 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1l8b |
RMSD bond length | 0.007 |
RMSD bond angle | 0.975 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.950 |
High resolution limit [Å] | 1.900 | 1.900 |
Rmerge | 0.078 | 0.587 |
Number of reflections | 62076 | |
<I/σ(I)> | 11.88 | 1.99 |
Completeness [%] | 98.2 | 97.6 |
Redundancy | 2.919 | 2.971 |
CC(1/2) | 0.997 | 0.720 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 291 | 12% PEG 10000, 0.2M CH3COONa, 0.1M TRIS pH 8.0 |