5LWD
Thermolysin in complex with inhibitor (JC96)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-12-14 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.91841 |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 92.795, 92.795, 130.629 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 31.751 - 1.230 |
R-factor | 0.1049 |
Rwork | 0.104 |
R-free | 0.12260 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 8tln |
RMSD bond length | 0.010 |
RMSD bond angle | 1.176 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.300 |
High resolution limit [Å] | 1.230 | 1.230 |
Rmerge | 0.473 | |
Number of reflections | 96448 | |
<I/σ(I)> | 36.27 | |
Completeness [%] | 99.7 | 98.8 |
Redundancy | 24.86 | 7.31 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 291.15 | 50 MM TRIS/HCL, 1.9 M CSCL, 50% DMSO |