5L7G
MCR IN COMPLEX WITH ligand
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID29 |
| Synchrotron site | ESRF |
| Beamline | ID29 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2015-04-15 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 0.976 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 48.635, 77.704, 78.314 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 41.320 - 2.010 |
| R-factor | 0.209 |
| Rwork | 0.207 |
| R-free | 0.24340 |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.000 |
| Data reduction software | MOSFLM |
| Data scaling software | Aimless |
| Refinement software | BUSTER (2.11.6 PACIOREK) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 48.630 |
| High resolution limit [Å] | 2.010 |
| Rmerge | 0.145 |
| Number of reflections | 20315 |
| <I/σ(I)> | 11.4 |
| Completeness [%] | 99.6 |
| Redundancy | 6.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | EVAPORATION | 293 | 0.9 M AMS 0.1 M CHES pH 9.5 +10% Morpheus C9 |