Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5KY0

mouse POFUT1 in complex with mouse Notch1 EGF12(D464G) and GDP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]100
Detector technologyCCD
Collection date2012-04-01
DetectorRAYONIX MX-300
Wavelength(s)0.97949
Spacegroup nameP 21 21 21
Unit cell lengths52.101, 66.476, 110.277
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution47.108 - 1.530
R-factor0.1448
Rwork0.144
R-free0.16410
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.392
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (dev_1405)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.590
High resolution limit [Å]1.5301.530
Rmerge0.0520.626
Number of reflections58604
<I/σ(I)>202.79
Completeness [%]100.0100
Redundancy7.36.8
CC(1/2)1.0000.842
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.529525% PEG 2000 MME 50mM Tris pH8.5

219869

PDB entries from 2024-05-15