5KXH

mouse POFUT1 in complex with mouse Factor VII EGF1 and GDP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]100
Detector technologyCCD
Collection date2012-04-01
DetectorRAYONIX MX-300
Wavelength(s)0.97949
Spacegroup nameP 21 21 21
Unit cell lengths51.970, 66.540, 110.640
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution47.039 - 1.330
R-factor0.1529
Rwork0.152
R-free0.16970
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.005
RMSD bond angle0.901
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.10.1_2155)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.0391.380
High resolution limit [Å]1.3281.330
Rmerge0.1071.024
Number of reflections87243
<I/σ(I)>9.21.2
Completeness [%]98.087
Redundancy7.15.7
CC(1/2)0.9950.467
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.529520% PEG 2000 MME 50mM Tris 8.5

219869