Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]173
Detector technologyCCD
Collection date2014-10-29
DetectorRAYONIX MX300-HS
Wavelength(s)1.0
Spacegroup nameP 21 21 21
Unit cell lengths113.611, 115.520, 257.822
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.954 - 3.312
R-factor0.2402
Rwork0.239
R-free0.26850
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1nbf
RMSD bond length0.004
RMSD bond angle0.808
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwarePHENIX (dev_2210)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]46.954115.4503.284
High resolution limit [Å]3.27315.1823.273
Rmerge0.1270.0360.853
Rmeas0.139
Rpim0.055
Total number of observations323509
Number of reflections52986
<I/σ(I)>11.4
Completeness [%]100.098.599.6
Redundancy6.156.3
CC(1/2)0.998
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52770.2 M K chloride, 0.05 M HEPES pH 7.5 and 35% v/v Pentaerythritol propoxylate