5JR5
RHCC in Complex with Elemental Sulfur
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2012-07-04 |
Detector | RIGAKU RAXIS IV++ |
Wavelength(s) | 1.54192 |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 110.520, 110.520, 71.040 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 25.751 - 1.900 |
R-factor | 0.185 |
Rwork | 0.182 |
R-free | 0.20660 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1fe6 |
RMSD bond length | 0.011 |
RMSD bond angle | 1.107 |
Data reduction software | iMOSFLM |
Data scaling software | SCALA |
Phasing software | REFMAC |
Refinement software | PHENIX (1.8.4_1496) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 25.751 |
High resolution limit [Å] | 1.900 |
Number of reflections | 39292 |
<I/σ(I)> | 6.2 |
Completeness [%] | 98.9 |
Redundancy | 4.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 277 | 1.6M ammonium sulfate and 100 mM Tris pH 8.0 |