5IWT

Structure of Transient Receptor Potential (TRP) channel TRPV6 in the presence of gadolinium

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]100
Detector technologyPIXEL
Collection date2015-08-25
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)1.7101
Spacegroup nameP 4 21 2
Unit cell lengths144.350, 144.350, 113.370
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution49.556 - 3.800
R-factor0.2766
Rwork0.275
R-free0.30740
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2rfa
RMSD bond length0.008
RMSD bond angle1.384
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0003.936
High resolution limit [Å]3.8003.800
Rmerge0.0891.207
Number of reflections22443
<I/σ(I)>19.41.6
Completeness [%]99.597.3
Redundancy11.46.4
CC(1/2)0.999
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION29320-24% PEG 350 MME, 50 mM NaCl, and 50 mM Tris-HCl pH 8.0-8.5