5ISK
Endothiapepsin in complex with fluorinated primary amine fragment
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ELETTRA BEAMLINE 5.2R |
Synchrotron site | ELETTRA |
Beamline | 5.2R |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2016-02-10 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 1.0000 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 45.133, 72.870, 52.718 |
Unit cell angles | 90.00, 109.28, 90.00 |
Refinement procedure
Resolution | 42.602 - 1.140 |
R-factor | 0.1208 |
Rwork | 0.119 |
R-free | 0.14570 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3pcw |
RMSD bond length | 0.007 |
RMSD bond angle | 1.228 |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.8.4_1492) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 42.600 | 1.210 |
High resolution limit [Å] | 1.140 | 1.140 |
Rmerge | 0.488 | |
Number of reflections | 116418 | |
<I/σ(I)> | 16.8 | 2.54 |
Completeness [%] | 99.5 | 99.1 |
Redundancy | 3.3 | 3.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4.6 | 290 | 0.1 M ammonium acetate, 0.1 M sodium acetate, 24-30% PEG 4000; crystals obtained by streak-seeding |