Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 HF |
| Temperature [K] | 95 |
| Detector technology | CCD |
| Collection date | 2008-04-23 |
| Detector | RIGAKU SATURN 944 |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 62.710, 111.000, 159.990 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 2.060 |
| High resolution limit [Å] | 2.000 | 2.000 |
| Rmerge | 0.094 | 0.488 |
| Number of reflections | 75540 | |
| <I/σ(I)> | 21.6 | 5 |
| Completeness [%] | 99.7 | 96.9 |
| Redundancy | 11.6 | 9.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 293 | 2.0 M AMMONIUM SULFATE, 2% PEG 400, 0.1 M HEPES PH 7.5 |