Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PAL/PLS BEAMLINE 7A (6B, 6C1) |
Synchrotron site | PAL/PLS |
Beamline | 7A (6B, 6C1) |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2010-07-29 |
Detector | ADSC QUANTUM 270 |
Wavelength(s) | 1.2398 |
Spacegroup name | P 1 |
Unit cell lengths | 40.269, 41.501, 85.091 |
Unit cell angles | 89.99, 90.01, 98.90 |
Refinement procedure
Resolution | 39.780 - 2.800 |
R-factor | 0.217 |
Rwork | 0.217 |
R-free | 0.22700 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4xg2 |
RMSD bond length | 0.007 |
RMSD bond angle | 1.565 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | REFMAC (5.8.0103) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 39.780 | 2.850 |
High resolution limit [Å] | 2.800 | 2.800 |
Number of reflections | 12408 | |
<I/σ(I)> | 30.18 | |
Completeness [%] | 99.7 | |
Redundancy | 5.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 278 | 10~20%(V/V) PEG3350, 100 MM TRIS-HCL |