Aedes aegypti GSTe2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2013-06-28
DetectorDECTRIS PILATUS 6M
Spacegroup nameP 21 21 21
Unit cell lengths48.811, 86.563, 101.021
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution27.745 - 1.431
R-factor0.1359
Rwork0.134
R-free0.17400
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3zml
RMSD bond length0.005
RMSD bond angle0.960
Data reduction softwareSCALA
Phasing softwareMOLREP
Refinement softwarePHENIX ((PHENIX.REFINE))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]28.8501.470
High resolution limit [Å]1.4301.430
Rmerge0.0600.590
Number of reflections78165
<I/σ(I)>18.82.1
Completeness [%]98.080.7
Redundancy5.72.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
10.2 M NACL, 0.1 M BIS-TRIS PH 5.7, 25 % PEG 3350

219869