5FMS
mmIFT52 N-terminal domain
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06DA |
Synchrotron site | SLS |
Beamline | X06DA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Detector | DECTRIS PILATUS 2M-F |
Spacegroup name | P 43 3 2 |
Unit cell lengths | 204.910, 204.910, 204.910 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.298 - 3.488 |
R-factor | 0.2317 |
Rwork | 0.229 |
R-free | 0.28850 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5fmr |
RMSD bond length | 0.018 |
RMSD bond angle | 1.602 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHENIX |
Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.300 | 3.610 |
High resolution limit [Å] | 3.490 | 3.490 |
Rmerge | 0.380 | 1.500 |
Number of reflections | 35358 | |
<I/σ(I)> | 11.29 | 1.65 |
Completeness [%] | 99.6 | 98 |
Redundancy | 21 | 20.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 100 MM BIS-TRIS PH5.5, 1.8 M AMMONIUM SULFATE |