5F4P

HIV-1 gp120 complex with BNM-III-170

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]180
Detector technologyPIXEL
Collection date2015-04-17
DetectorPSI PILATUS 6M
Wavelength(s)0.9792
Spacegroup nameC 2 2 21
Unit cell lengths67.378, 127.517, 192.945
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.236 - 2.600
R-factor0.2754
Rwork0.274
R-free0.31050
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3tgr
RMSD bond length0.006
RMSD bond angle1.064
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.8.4_1496)
Data quality characteristics
 Overall
Low resolution limit [Å]48.236
High resolution limit [Å]2.500
Rmerge0.092
Number of reflections26041
<I/σ(I)>12.1
Completeness [%]99.2
Redundancy6.29
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1EVAPORATION290PEG 1500, calcium magnesium chloride, imidazole

219869