Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5EYP

TUBULIN-DARPIN COMPLEX

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 1
Synchrotron siteSOLEIL
BeamlinePROXIMA 1
Temperature [K]100
Detector technologyPIXEL
Collection date2014-09-21
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.97918
Spacegroup nameP 1 21 1
Unit cell lengths87.570, 71.760, 93.050
Unit cell angles90.00, 99.85, 90.00
Refinement procedure
Resolution49.740 - 1.900
R-factor0.1752
Rwork0.173
R-free0.20800
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4drx
RMSD bond length0.010
RMSD bond angle1.040
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]1.950
High resolution limit [Å]1.9001.900
Rmerge0.106
<I/σ(I)>1.01
Completeness [%]100.0100
Redundancy99
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.6293PEG 4000, tri-sodium citrate, ammonium sulfate

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon