Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5DHY

HIV-1 Rev NTD dimers with variable crossing angles

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I02
Synchrotron siteDiamond
BeamlineI02
Temperature [K]80
Detector technologyPIXEL
Collection date2010-07-01
DetectorPSI PILATUS 6M
Wavelength(s)0.9793
Spacegroup nameI 4
Unit cell lengths121.140, 121.140, 89.270
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution33.390 - 3.100
R-factor0.2919
Rwork0.291
R-free0.30020
RMSD bond length0.008
RMSD bond angle1.140
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareBUSTER (2.9.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]60.8003.200
High resolution limit [Å]3.1003.100
Number of reflections11655
<I/σ(I)>15.12.7
Completeness [%]99.897.6
Redundancy7.57.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293Crystals of scFv-Rev were initially grown in 20% PEG 3350, a variety of salts (200 mM sodium sulfate, sodium bromide, or ammonium phosphate dibasic), and pH ranging from 6.5-8.5

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon