Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4ZJW

RORgamma in complex with inverse agonist 16

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 31-ID
Synchrotron siteAPS
Beamline31-ID
Temperature [K]100
Detector technologyCCD
Collection date2011-10-20
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.9793
Spacegroup nameC 1 2 1
Unit cell lengths125.586, 56.313, 79.517
Unit cell angles90.00, 124.66, 90.00
Refinement procedure
Resolution60.640 - 2.500
R-factor0.1927
Rwork0.190
R-free0.25030
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3bow
RMSD bond length0.013
RMSD bond angle1.655
Data reduction softwareHKL-2000
Data scaling softwareSCALA (3.2.5)
Refinement softwareREFMAC (5.8.0107)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]33.5772.560
High resolution limit [Å]1.3512.490
Rmerge0.1790.164
Total number of observations14687721263
Number of reflections39149
<I/σ(I)>4.61.2
Completeness [%]99.9
Redundancy3.83.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.52980.2M Ammonium Acetate. 15% PEG3350, 0.1M BisTRIS pH 5.5

222926