4YP1
Misting with CDA
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSRRC BEAMLINE BL13B1 |
Synchrotron site | NSRRC |
Beamline | BL13B1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2013-04-23 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1.0000 |
Spacegroup name | P 2 21 21 |
Unit cell lengths | 45.427, 48.208, 172.420 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 50.000 - 2.650 |
R-factor | 0.21 |
Rwork | 0.210 |
R-free | 0.26000 |
Structure solution method | MOLECULAR REPLACEMENT |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | CNS |
Refinement software | CNS |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.780 |
High resolution limit [Å] | 2.650 | 2.650 |
Number of reflections | 12171 | |
<I/σ(I)> | 11.9 | |
Completeness [%] | 94.6 | 94.6 |
Redundancy | 6.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8 | 298 | 100MM TRIS 8.0, PEG 3350 20%, VAPOR DIFFUSION, SITTING DROP |