Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4YHU

Yeast Prp3 C-terminal fragment 296-469

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.2
Synchrotron siteBESSY
Beamline14.2
Temperature [K]100
Detector technologyCCD
Collection date2012-05-30
DetectorRAYONIX MX-225
Wavelength(s)0.91841
Spacegroup nameC 2 2 21
Unit cell lengths87.663, 161.205, 105.214
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution30.000 - 2.700
R-factor0.20946
Rwork0.207
R-free0.26241
Structure solution methodMAD
RMSD bond length0.010
RMSD bond angle1.316
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareMOLREP
Refinement softwareREFMAC (5.5.0110)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.120
High resolution limit [Å]2.0002.000
Rmerge0.0660.791
Number of reflections20036
<I/σ(I)>24.965.95
Completeness [%]99.396.2
Redundancy11.411.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2910.1 M HEPES, pH 7.5, 10 % PEG 8000

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon