Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | CHESS BEAMLINE A1 |
Synchrotron site | CHESS |
Beamline | A1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2010-11-04 |
Detector | ADSC QUANTUM 210 |
Wavelength(s) | 0.9770 |
Spacegroup name | P 63 2 2 |
Unit cell lengths | 165.750, 165.750, 263.846 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 47.070 - 2.750 |
R-factor | 0.194 |
Rwork | 0.193 |
R-free | 0.23000 |
Structure solution method | SIRAS |
RMSD bond length | 0.010 |
RMSD bond angle | 13.595 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX ((PHENIX.REFINE: 1.8_1069)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.800 |
High resolution limit [Å] | 2.750 | 2.750 |
Number of reflections | 56095 | |
<I/σ(I)> | 18.8 | 1.7 |
Completeness [%] | 99.8 | 99.6 |
Redundancy | 7.3 | 6.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.4 | 299 | 0.35 M POTASSIUM CHLORIDE, 3 MM DITHIOTHREITOL, 10 MM HEPES PH 7.4, 150 MM NACL, VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 299K |