Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SPRING-8 BEAMLINE BL41XU |
Synchrotron site | SPring-8 |
Beamline | BL41XU |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2005-07-13 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.8000 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 63.039, 96.029, 155.418 |
Unit cell angles | 90.00, 95.09, 90.00 |
Refinement procedure
Resolution | 15.979 - 3.250 |
R-factor | 0.1991 |
Rwork | 0.197 |
R-free | 0.23680 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1iwo |
RMSD bond length | 0.002 |
RMSD bond angle | 0.566 |
Data scaling software | DENZO |
Refinement software | PHENIX ((phenix.refine: 1.9_1692)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 3.250 |
Number of reflections | 28651 |
<I/σ(I)> | 30.1 |
Completeness [%] | 97.7 |
Redundancy | 6.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | MICRODIALYSIS | 6.1 | 283 | PEG 400, pH 6.1, MICRODIALYSIS, temperature 283K |