Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4YAU

Reduced CYPOR mutant - G141del/E142N

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2014-04-01
DetectorRIGAKU RAXIS IV++
Wavelength(s)1.5418
Spacegroup nameP 21 21 21
Unit cell lengths101.557, 115.901, 118.607
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.680 - 2.200
R-factor0.201
Rwork0.201
R-free0.24100
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1amo
RMSD bond length0.006
RMSD bond angle1.300
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwareCNS (1.3)
Data quality characteristics
 Overall
Low resolution limit [Å]46.680
High resolution limit [Å]2.200
Number of reflections68312
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7292PEG 4000, Sodium Acetate, HEPES

223532

PDB entries from 2024-08-07