Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4Y5F

PAS-GAF fragment from Deinococcus radiodurans BphP assembled with BV - Y307S, high dose

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X25
Synchrotron siteNSLS
BeamlineX25
Temperature [K]100
Detector technologyPIXEL
Collection date2013-08-05
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.1
Spacegroup nameC 1 2 1
Unit cell lengths89.274, 51.803, 80.272
Unit cell angles90.00, 116.22, 90.00
Refinement procedure
Resolution50.000 - 1.700
R-factor0.14643
Rwork0.143
R-free0.21393
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2o9c
RMSD bond length0.017
RMSD bond angle2.043
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Refinement softwareREFMAC (5.8.0073)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.740
High resolution limit [Å]1.7001.700
Rmerge0.1050.459
Number of reflections33245
<I/σ(I)>251.8
Completeness [%]96.276.7
Redundancy6.82.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.629610% PEG3350, 19% isopropanol, 5% glycerol, 100 mM citric acid/NaOH, ph 5.6

223166

PDB entries from 2024-07-31

PDB statisticsPDBj update infoContact PDBjnumon