4Y54
Endothiapepsin in complex with fragment 56
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-11-18 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.891200 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 45.132, 72.690, 52.603 |
Unit cell angles | 90.00, 109.63, 90.00 |
Refinement procedure
Resolution | 27.952 - 1.610 |
R-factor | 0.1522 |
Rwork | 0.150 |
R-free | 0.18710 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3pcw |
RMSD bond length | 0.009 |
RMSD bond angle | 1.224 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.8.4_1492) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 42.510 | 1.710 |
High resolution limit [Å] | 1.610 | 1.610 |
Rmerge | 0.465 | |
Number of reflections | 40942 | |
<I/σ(I)> | 16.92 | 3.31 |
Completeness [%] | 98.5 | 92.3 |
Redundancy | 4.1 | 3.53 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4.6 | 290 | 0.1 M ammonium acetate, 0.1 M sodium acetate, 24-30% PEG 4000 |