4Y3T
Endothiapepsin in complex with fragment 207
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.2 |
Synchrotron site | BESSY |
Beamline | 14.2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2013-04-18 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.918410 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 45.320, 72.924, 52.594 |
Unit cell angles | 90.00, 109.35, 90.00 |
Refinement procedure
Resolution | 39.507 - 1.420 |
R-factor | 0.1184 |
Rwork | 0.117 |
R-free | 0.15020 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3pcw |
RMSD bond length | 0.007 |
RMSD bond angle | 1.216 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (dev_1779) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 42.759 | 1.500 |
High resolution limit [Å] | 1.420 | 1.420 |
Rmerge | 0.503 | |
Number of reflections | 60833 | |
<I/σ(I)> | 14.33 | 2.99 |
Completeness [%] | 99.0 | 95.2 |
Redundancy | 3.5 | 3.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4.6 | 290 | 0.1 M ammonium acetate, 0.1 M sodium acetate, 24-30% PEG 4000. Crystals obtained by streak-seeding |