4XRC
Antibody hemagglutinin Complexes
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 21-ID-G |
Synchrotron site | APS |
Beamline | 21-ID-G |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-04-03 |
Detector | RAYONIX MX-300 |
Wavelength(s) | 0.97856 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 248.420, 51.080, 127.610 |
Unit cell angles | 90.00, 99.94, 90.00 |
Refinement procedure
Resolution | 41.918 - 2.740 |
R-factor | 0.1945 |
Rwork | 0.192 |
R-free | 0.24780 |
RMSD bond length | 0.004 |
RMSD bond angle | 0.907 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (dev_1760) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.810 |
High resolution limit [Å] | 2.740 | 2.740 |
Rmerge | 0.598 | |
Number of reflections | 42101 | |
<I/σ(I)> | 14.5 | 2.2 |
Completeness [%] | 99.8 | 99.8 |
Redundancy | 5.1 | 4.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 294 | 200 mM ammonium sulfate, 100 mM HEPES pH 7.5, 25% PEG 3350. |