4XPM
Crystal structure of EGO-TC
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL17U |
| Synchrotron site | SSRF |
| Beamline | BL17U |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2014-09-28 |
| Detector | RAYONIX MX225HE |
| Wavelength(s) | 0.9794 |
| Spacegroup name | P 41 21 2 |
| Unit cell lengths | 48.118, 48.118, 223.377 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 40.414 - 2.400 |
| R-factor | 0.1728 |
| Rwork | 0.171 |
| R-free | 0.21670 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4ftx 3ms6 |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.087 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX (1.8.1_1168) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.490 |
| High resolution limit [Å] | 2.400 | 2.400 |
| Rmerge | 0.076 | 0.520 |
| Number of reflections | 11033 | |
| <I/σ(I)> | 18.7 | 4.6 |
| Completeness [%] | 99.7 | 99.7 |
| Redundancy | 6.2 | 6.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 5.5 | 289 | 0.2M NaCl, 0.1M Bis-Tris (pH 5.5), 25% PEG 3350 |