4XNM
Antibody Influenza H5 Complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-G |
| Synchrotron site | APS |
| Beamline | 21-ID-G |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2013-10-09 |
| Detector | RAYONIX MX-300 |
| Wavelength(s) | 0.97856 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 250.939, 51.427, 127.181 |
| Unit cell angles | 90.00, 99.83, 90.00 |
Refinement procedure
| Resolution | 29.464 - 2.510 |
| R-factor | 0.2149 |
| Rwork | 0.214 |
| R-free | 0.24120 |
| RMSD bond length | 0.002 |
| RMSD bond angle | 0.659 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((phenix.refine: dev_1760)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.590 |
| High resolution limit [Å] | 2.510 | 2.510 |
| Rmerge | 0.660 | |
| Number of reflections | 53874 | |
| <I/σ(I)> | 14.2 | 1.7 |
| Completeness [%] | 97.6 | 94.3 |
| Redundancy | 4.9 | 3.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 294 | 20% PEG 10,000 |