4X6B
BK6 TCR apo structure
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX1 |
Synchrotron site | Australian Synchrotron |
Beamline | MX1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-12-12 |
Detector | ADSC QUANTUM 210r |
Wavelength(s) | 0.98 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 74.320, 78.998, 89.590 |
Unit cell angles | 90.00, 105.78, 90.00 |
Refinement procedure
Resolution | 48.900 - 2.100 |
R-factor | 0.1897 |
Rwork | 0.188 |
R-free | 0.22920 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4pj5 |
RMSD bond length | 0.010 |
RMSD bond angle | 1.080 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | BUSTER (2.10.0) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 48.900 |
High resolution limit [Å] | 2.100 |
Number of reflections | 58406 |
<I/σ(I)> | 8.2 |
Completeness [%] | 100.0 |
Redundancy | 3.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 293 | 0.1 M bicine, 20% PEG 6000 |