4X4B
RADIATION DAMAGE TO THE NUCLEOPROTEIN COMPLEX C.Esp1396I: DOSE (DWD) 2.1 MGy
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID29 |
| Synchrotron site | ESRF |
| Beamline | ID29 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2007-09-29 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.9322 |
| Spacegroup name | P 65 |
| Unit cell lengths | 104.310, 104.310, 139.130 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 19.028 - 2.800 |
| R-factor | 0.2075 |
| Rwork | 0.204 |
| R-free | 0.26160 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 3clc |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.338 |
| Data reduction software | MOSFLM |
| Data scaling software | Aimless (0.2.8) |
| Phasing software | PHASER |
| Refinement software | PHENIX |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 69.590 | 69.590 | 2.990 |
| High resolution limit [Å] | 2.800 | 7.920 | 2.800 |
| Rmerge | 0.049 | 0.021 | 0.330 |
| Rpim | 0.022 | 0.010 | 0.145 |
| Total number of observations | 128219 | 5295 | 23753 |
| Number of reflections | 21172 | ||
| <I/σ(I)> | 24 | 55.3 | 5.5 |
| Completeness [%] | 99.9 | 96.7 | 100 |
| Redundancy | 6.1 | 5.7 | 6.2 |
| CC(1/2) | 0.996 | 0.990 | 0.950 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 293.15 | MES, MPD, MgCl2 |