Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4X37

Gallus interleukin-1 mutant - E118K

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSRRC BEAMLINE BL13B1
Synchrotron siteNSRRC
BeamlineBL13B1
Temperature [K]100
Detector technologyCCD
Collection date2014-11-04
DetectorADSC QUANTUM 315r
Wavelength(s)1
Spacegroup nameP 21 21 21
Unit cell lengths35.576, 102.501, 37.821
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution29.200 - 1.630
R-factor0.19915
Rwork0.198
R-free0.22893
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2wry
RMSD bond length0.025
RMSD bond angle2.457
Data scaling softwareDENZO (HKL-2000)
Refinement softwareREFMAC (5.8.0073)
Data quality characteristics
 Overall
Low resolution limit [Å]29.200
High resolution limit [Å]1.630
Number of reflections17881
<I/σ(I)>66.87
Completeness [%]98.7
Redundancy8.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2931.15 M (NH4)2SO4, 0.1 M Tris, 0.2 M LiSO4

219515

PDB entries from 2024-05-08

PDB statisticsPDBj update infoContact PDBjnumon