Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4WU5

HLA-A24 in complex with HIV-1 Nef134-8(wt)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSPRING-8 BEAMLINE BL41XU
Synchrotron siteSPring-8
BeamlineBL41XU
Temperature [K]100
Detector technologyCCD
Collection date2011-10-29
DetectorRAYONIX MX225HE
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths57.687, 67.070, 117.727
Unit cell angles90.00, 99.01, 90.00
Refinement procedure
Resolution50.000 - 2.400
R-factor0.2333
Rwork0.231
R-free0.27090
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3vxn
RMSD bond length0.007
RMSD bond angle0.925
Data reduction softwareSCALA
Refinement softwareREFMAC (5.6.0117)
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]2.400
Number of reflections35040
<I/σ(I)>17.4
Completeness [%]97.7
Redundancy5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29320% PEG 3350, 200 mM sodium nitrate

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon