4WII
HUMAN SPLICING FACTOR, CONSTRUCT 3
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX1 |
Synchrotron site | Australian Synchrotron |
Beamline | MX1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2010-10-15 |
Detector | ADSC QUANTUM 210r |
Wavelength(s) | 0.9686 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 63.447, 67.611, 119.528 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.520 - 2.050 |
R-factor | 0.201 |
Rwork | 0.199 |
R-free | 0.23500 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.010 |
RMSD bond angle | 1.040 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | BUSTER (2.10.0) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.610 | 2.160 |
High resolution limit [Å] | 2.050 | 2.050 |
Number of reflections | 32938 | |
<I/σ(I)> | 13.1 | 2.1 |
Completeness [%] | 99.9 | 100 |
Redundancy | 7.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 293 | 1.9 M AMMONIUM SULFATE, 0.1 M TRIS, 20% ETHYLENE GLYCOL (V/V), PH 8.5, VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 293K |