Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4WIC

Immediate-early 1 protein (IE1) of rhesus macaque cytomegalovirus

Experimental procedure
Experimental methodMAD
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyCCD
Collection date2011-09-16
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.9184, 1.0402, 1.0372, 1.0346, 0.9797
Spacegroup nameP 1 21 1
Unit cell lengths57.950, 278.550, 61.620
Unit cell angles90.00, 90.90, 90.00
Refinement procedure
Resolution19.935 - 2.850
R-factor0.2142
Rwork0.212
R-free0.25940
Structure solution methodMAD
RMSD bond length0.011
RMSD bond angle1.438
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareSHARP
Refinement softwarePHENIX ((phenix.refine: 1.8.4_1496))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0002.920
High resolution limit [Å]2.8502.850
Number of reflections45137
<I/σ(I)>16.9
Completeness [%]99.599.7
Redundancy3.71.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP293.15Reservoir 700 microL: 15 % (w/v) PEG 3350, 400 mM magnesium formate Drop ratio: 1 to 2 microL protein solution (20 mg/mL) plus 1 microL of reservoir solution supplemented with microseeds

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon