4W5M

Prp peptide

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 19-ID
Synchrotron siteAPS
Beamline19-ID
Temperature [K]100
Detector technologyCCD
Collection date2009-08-23
DetectorADSC QUANTUM 315r
Wavelength(s)0.97940
Spacegroup nameC 1 2 1
Unit cell lengths47.481, 9.437, 22.621
Unit cell angles90.00, 95.18, 90.00
Refinement procedure
Resolution23.644 - 1.200
R-factor0.1955
Rwork0.193
R-free0.25640
Structure solution methodMOLECULAR REPLACEMENT
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareSHELX
Refinement softwarePHENIX ((phenix.refine: 1.9_1692))
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0001.240
High resolution limit [Å]1.2002.5901.200
Rmerge0.0710.0650.099
Total number of observations7028
Number of reflections2911
<I/σ(I)>11.1
Completeness [%]86.985.249.2
Redundancy2.42.51.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.52930.1 M Bis-tris, 2% 2-methyl-2,4-pentanediol (MPD), and 1.1 M ammonium sulfate