Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2008-12-04 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.97949 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 210.230, 448.510, 633.620 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 50.000 - 3.000 |
Rwork | 0.248 |
R-free | 0.27200 |
Structure solution method | MOLECULAR REPLACEMENT |
Data scaling software | XSCALE |
Phasing software | PHASER (1.4) |
Refinement software | CNS |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 3.080 |
High resolution limit [Å] | 3.000 | 13.420 | 3.000 |
Rmerge | 0.307 | 0.014 | 0.014 |
Number of reflections | 1121164 | 13489 | 42523 |
<I/σ(I)> | 3.86 | 11.9 | 0.3 |
Completeness [%] | 95.1 | 96.1 | 49.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 7.6 | 292 | 0.1-0.2 M Arginine-HCL, 0.1 M Tris pH 7.6, 2.5% Peg 20K, 7-12% MPD, 0.5 mM BME, vapor diffusion, temperature 292K |