Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID14-4 |
Synchrotron site | ESRF |
Beamline | ID14-4 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2004-04-15 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.934 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 307.585, 302.265, 181.923 |
Unit cell angles | 90.00, 92.77, 90.00 |
Refinement procedure
Resolution | 12.000 - 1.450 |
R-factor | 0.17633 |
Rwork | 0.175 |
R-free | 0.20761 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2STV |
RMSD bond length | 0.009 |
RMSD bond angle | 1.220 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | AMoRE |
Refinement software | REFMAC (5.5.0066) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 35.000 |
High resolution limit [Å] | 1.450 |
Rmerge | 0.100 |
Number of reflections | 2217504 |
<I/σ(I)> | 3.6 |
Completeness [%] | 80.2 |
Redundancy | 1.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.2 | 298 | 0.4 % PEG 6000, pH 6.2, 1 mM MgCl2, VAPOR DIFFUSION, HANGING DROP, temperature 298K |