4V2A
human Unc5A ectodomain
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Detector | PILATUS |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 25.830, 87.770, 133.820 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 43.880 - 2.400 |
R-factor | 0.3276 |
Rwork | 0.327 |
R-free | 0.34360 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | NONE |
RMSD bond length | 0.007 |
RMSD bond angle | 0.850 |
Data reduction software | xia2 |
Data scaling software | xia2 |
Phasing software | PHASER |
Refinement software | BUSTER (2.11.2) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 44.000 | 2.460 |
High resolution limit [Å] | 2.400 | 2.400 |
Rmerge | 0.110 | |
Number of reflections | 11029 | |
<I/σ(I)> | 13.88 | 0.61 |
Completeness [%] | 86.8 | 46.5 |
Redundancy | 6.6 | 4.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |