4UAD

Importin alpha 7 delta IBB in complex with Influenza PB2 Nuclear Localization Domain

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X6A
Synchrotron siteNSLS
BeamlineX6A
Temperature [K]100
Detector technologyCCD
Collection date2012-06-19
DetectorADSC QUANTUM 270
Wavelength(s)0.972
Spacegroup nameC 1 2 1
Unit cell lengths242.315, 38.836, 67.898
Unit cell angles90.00, 98.03, 90.00
Refinement procedure
Resolution14.860 - 2.420
R-factor0.1928
Rwork0.189
R-free0.23100
RMSD bond length0.003
RMSD bond angle0.719
Refinement softwarePHENIX ((phenix.refine: 1.9_1692))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]15.0002.510
High resolution limit [Å]2.4202.420
Number of reflections21920
<I/σ(I)>24.9
Completeness [%]90.060.4
Redundancy3.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2980.2 M magnesium acetate 12% PEG 8000 0.1M Na cacodylate at pH 6.5