4U6J

HsMetAP in complex with methionine

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007 HF
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2014-03-11
DetectorRIGAKU RAXIS IV++
Wavelength(s)1.54
Spacegroup nameP 1 21 1
Unit cell lengths47.446, 77.340, 48.440
Unit cell angles90.00, 90.93, 90.00
Refinement procedure
Resolution18.530 - 1.560
R-factor0.127
Rwork0.125
R-free0.17600
RMSD bond length0.021
RMSD bond angle2.057
Refinement softwareREFMAC (5.7.0029)
Data quality characteristics
 Overall
Low resolution limit [Å]18.930
High resolution limit [Å]1.560
Number of reflections48263
<I/σ(I)>4.8
Completeness [%]97.0
Redundancy3.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP629815% PEG MME , 100mM HEPES PH6.0 ,

222926