4S3O
PCGF5-RING1B-UbcH5c complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.2 |
Synchrotron site | ALS |
Beamline | 5.0.2 |
Temperature [K] | 110 |
Detector technology | CCD |
Collection date | 2013-06-13 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1.00003 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 54.392, 105.285, 132.417 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.919 - 2.000 |
R-factor | 0.1961 |
Rwork | 0.194 |
R-free | 0.23680 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3rpg chains A and C |
RMSD bond length | 0.009 |
RMSD bond angle | 1.143 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: 1.8.2_1309)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 2.000 |
Number of reflections | 52191 |
<I/σ(I)> | 22.5 |
Completeness [%] | 99.8 |
Redundancy | 7.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 6.5 | 277 | 13.5% PEG 550 MME, 10 mM TCEP, 0.1 M MES pH 6.5, 100 mM KCl, VAPOR DIFFUSION, temperature 277K |