4QW4
yCP in complex with carfilzomib
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-03-16 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 1.0 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 135.810, 298.690, 145.700 |
Unit cell angles | 90.00, 112.69, 90.00 |
Refinement procedure
Resolution | 15.000 - 2.800 |
R-factor | 0.18861 |
Rwork | 0.187 |
R-free | 0.21636 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1ryp |
RMSD bond length | 0.005 |
RMSD bond angle | 0.865 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | REFMAC |
Refinement software | REFMAC |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 2.900 |
High resolution limit [Å] | 2.800 | 2.800 |
Rmerge | 0.082 | 0.544 |
Number of reflections | 254230 | |
<I/σ(I)> | 10.4 | 2.3 |
Completeness [%] | 96.9 | 98 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.8 | 293 | 20 MM MGAC2, 13% MPD, PH 6.8, VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 293K |