4QAP
The second sphere residue T263 is important for function and activity of PTP1B through modulating WPD loop
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Detector | MARMOSAIC 225 mm CCD |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 88.470, 88.470, 104.558 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 30.901 - 1.903 |
R-factor | 0.2107 |
Rwork | 0.209 |
R-free | 0.24200 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.085 |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | PHASES |
Refinement software | PHENIX ((phenix.refine: 1.6.2_432)) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 1.970 |
High resolution limit [Å] | 1.900 | 4.090 | 1.900 |
Number of reflections | 36673 | ||
Completeness [%] | 99.7 | 97.5 | 100 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 277 | 8-24% (w/v) polyethylene glycol 4000, 100mM Hepes (pH 7.0), 200mM magnesium acetate, VAPOR DIFFUSION, HANGING DROP, temperature 277K |