4Q74
F241A Fc
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRL BEAMLINE BL12-2 |
| Synchrotron site | SSRL |
| Beamline | BL12-2 |
| Detector technology | PIXEL |
| Collection date | 2012-01-27 |
| Detector | DECTRIS PILATUS 6M |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 57.910, 74.700, 113.710 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 35.650 - 2.190 |
| Rwork | 0.206 |
| R-free | 0.23200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1h3x |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | PHASER |
| Refinement software | PHENIX (refine) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 35.650 |
| High resolution limit [Å] | 2.190 |
| Number of reflections | 44637 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293.15 | 30% PEG 1500 at 20 C and cryopreserved in well solution containing 25% glycerol, VAPOR DIFFUSION, HANGING DROP, temperature 293.15K |