4Q0I

Deinococcus radiodurans BphP PAS-GAF D207A mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X29A
Synchrotron siteNSLS
BeamlineX29A
Temperature [K]100
Detector technologyCCD
Collection date2011-12-11
DetectorADSC QUANTUM 315r
Wavelength(s)1.07500
Spacegroup nameC 1 2 1
Unit cell lengths87.497, 51.327, 80.368
Unit cell angles90.00, 115.75, 90.00
Refinement procedure
Resolution36.193 - 1.744
R-factor0.163
Rwork0.161
R-free0.19510
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.015
RMSD bond angle1.623
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.8.4_1496))
Data quality characteristics
 Overall
Low resolution limit [Å]36.500
High resolution limit [Å]1.744
Number of reflections32523
Completeness [%]99.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.629619% isopropano, 19% PEG 3350, 5% glycerol, 100 mM Citric acid(NaOH) pH 5.6, VAPOR DIFFUSION, SITTING DROP, temperature 296K