4OUU
anti-MT1-MMP monoclonal antibody
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-11-15 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.97628 |
Spacegroup name | P 1 2 1 |
Unit cell lengths | 66.140, 52.600, 127.500 |
Unit cell angles | 90.00, 103.68, 90.00 |
Refinement procedure
Resolution | 52.220 - 2.600 |
R-factor | 0.19933 |
Rwork | 0.197 |
R-free | 0.25271 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.013 |
RMSD bond angle | 1.612 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | REFMAC (5.7.0029) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 64.000 | 2.740 |
High resolution limit [Å] | 2.600 | 2.600 |
Rmerge | 0.112 | 0.525 |
Number of reflections | 26041 | |
<I/σ(I)> | 1.3 | |
Completeness [%] | 98.8 | 98.2 |
Redundancy | 3.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 298 | 0.2M Potassium Formate 20% PEG 3350, pH 7, VAPOR DIFFUSION, HANGING DROP, temperature 298K |