Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4OUU

anti-MT1-MMP monoclonal antibody

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]100
Detector technologyCCD
Collection date2012-11-15
DetectorADSC QUANTUM 315r
Wavelength(s)0.97628
Spacegroup nameP 1 2 1
Unit cell lengths66.140, 52.600, 127.500
Unit cell angles90.00, 103.68, 90.00
Refinement procedure
Resolution52.220 - 2.600
R-factor0.19933
Rwork0.197
R-free0.25271
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.013
RMSD bond angle1.612
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareREFMAC (5.7.0029)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]64.0002.740
High resolution limit [Å]2.6002.600
Rmerge0.1120.525
Number of reflections26041
<I/σ(I)>1.3
Completeness [%]98.898.2
Redundancy3.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP72980.2M Potassium Formate 20% PEG 3350, pH 7, VAPOR DIFFUSION, HANGING DROP, temperature 298K

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon