Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4OHW

C. Elegans Clp1 bound to ATP, and Mn2+(ATP-bound state)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X10SA
Synchrotron siteSLS
BeamlineX10SA
Temperature [K]100
Detector technologyPIXEL
Collection date2010-07-30
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9793
Spacegroup nameP 31
Unit cell lengths99.340, 99.340, 40.800
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution43.030 - 2.300
R-factor0.20398
Rwork0.202
R-free0.24096
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.006
RMSD bond angle0.832
Data reduction softwareXDS
Data scaling softwareXSCALE
Refinement softwareREFMAC (5.2.0005)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.400
High resolution limit [Å]2.3002.300
Number of reflections19707
Completeness [%]98.597
Redundancy3.63.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.5293100 mM Na2HPO4/KH2PO4 200 mM NaCl 15 mM MgCl2 90 mM sarcosine 25% (w/v) PEG 1000, pH 5.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K

223532

PDB entries from 2024-08-07