Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 5.0.2 |
| Synchrotron site | ALS |
| Beamline | 5.0.2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2007-11-07 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 1.0 |
| Spacegroup name | H 3 |
| Unit cell lengths | 131.787, 131.787, 119.107 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 41.203 - 3.000 |
| R-factor | 0.204 |
| Rwork | 0.202 |
| R-free | 0.24610 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.006 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX ((phenix.refine: dev_1402)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 80.000 |
| High resolution limit [Å] | 3.000 |
| Rmerge | 0.108 |
| Number of reflections | 15435 |
| <I/σ(I)> | 15.5 |
| Completeness [%] | 99.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 277 | 0.15-0.35 M SODIUM CHLORIDE, 0.1 M HEPES, 23-28% PEG 400, 0.01 M TAURINE, PH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K |