Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.2 |
Synchrotron site | ALS |
Beamline | 5.0.2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2007-11-07 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 1.0 |
Spacegroup name | H 3 |
Unit cell lengths | 131.787, 131.787, 119.107 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 41.203 - 3.000 |
R-factor | 0.204 |
Rwork | 0.202 |
R-free | 0.24610 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.006 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: dev_1402)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 80.000 |
High resolution limit [Å] | 3.000 |
Rmerge | 0.108 |
Number of reflections | 15435 |
<I/σ(I)> | 15.5 |
Completeness [%] | 99.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 277 | 0.15-0.35 M SODIUM CHLORIDE, 0.1 M HEPES, 23-28% PEG 400, 0.01 M TAURINE, PH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K |