Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4NXC

SPERM WHALE MYOGLOBIN UNDER 30 BAR NITROUS Oxide

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE BM16
Synchrotron siteESRF
BeamlineBM16
Temperature [K]298
Detector technologyCCD
Collection date2009-10-22
DetectorADSC QUANTUM 210r
Wavelength(s)0.979
Spacegroup nameP 1 21 1
Unit cell lengths35.449, 30.545, 63.634
Unit cell angles90.00, 104.57, 90.00
Refinement procedure
Resolution20.000 - 1.550
R-factor0.19141
Rwork0.190
R-free0.22455
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2jho
RMSD bond length0.010
RMSD bond angle3.040
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwareREFMAC
Refinement softwareREFMAC
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]1.630
High resolution limit [Å]1.5501.550
Number of reflections18602
<I/σ(I)>16.84.5
Completeness [%]95.393.9
Redundancy4.14.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1BATCH730050mM potassium phosphate, saturated ammonium sulphate., pH 7, BATCH, temperature 300K

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon